Fire Retardants Texas - Fort Worth/Dallas basedHotline: 800-333-9197 7am-5pm (CST) Ph: 817-740-9197 After Hours: 817-658-9197 / email: fireprod@aol.com |
---|
2653 Warfield Street Fort Worth, TX 76106 |
Dallas, Ft Worth, Austin, Houston, Corpus Christi, Wichita Falls, Abilene, Amarillo, Plano, North Dallas, El Paso, Laredo, Frisco, South Dallas, Lancaster, Dallas County, Tarrant County, Odessa, Waco, Midland, Tyler, Dallas, San Antonio,Lubbock, East Dallas, Grand Prairie, Irving, Dallas / Fort Worth metroplex |
---|
Home | About Us |
---|
FIRE POLY 75 I |
INTERIOR FIRE RETARDANT
COATING or SPRAY
FOR ALL INTERIOR WOOD
PLYWOOD ● LUMBER ● TIMBER
CLASSIFIED
FIRE RETARDANT COATING
SURFACE BURNING CHARACTERISTICS OF APPLIED COATING
Surface | Douglas fir |
Flame spread | 20 |
Smoke developed | 90 |
Number of preliminary coats | None |
Rate per coat (ft2/gal) | -- |
Number of fire retardant coats | 3 |
Rate per coat (ft2/gal) | 500 |
Number of overcoats | None |
Rate per coat (ft2/gal) | -- |
Flash point of liquid coating: | |
Fire retarding coating - closed cup, | no flash |
FIRE POLY 75 I TECHNICAL DATA
ASTM E-84 CLASS A UL 723 TYPE 1
PRODUCT DESCRIPTION: Aqueous Based Resin
Product |
Analysis |
||
---|---|---|---|
Total Solids | 46% |
PH |
2.5-2.8 |
Weight per gallon | 10.7lbs |
Flash point |
Non-Flammable |
Specific gravity | 1.33 |
Color | Water clear at 78°F. - Slight haze at 50°F. or lower |
Volatability | Non-Volatile |
Solvents | Water(Contains no petroleum or derivatives of petroleum) |
Anti-Fungus | Excellent Resistance |
Bacterial | Good Resistance |
Linear shrinkage | None |
Moisture Absorption | None |
Corrosive | Mildly |
Toxic | None (when dry) |
Insects, rodents, aspergilli And other types of molds |
Excellent resistance |
Termites | Excellent resistance |
Preservative for wood | Good |
Scrubability | 1000 cycles |
RECOMMENDED USE: Interior Class A Rating (Flame spread less than 25)
FLAME SAFE FIRE POLY 75 I is a fire retardant and wood preservative coating. It can be used on any type of wood, porous, or non-porous materials, such as:
Yellow pine | Redwood | Cedar |
Douglas Fir | Plywood | Wall Coverings |
Wafer Board (OSB) | Particle Board | Corrugated Board |
ENVIRONMENTAL REGULATION:
This product complies will U. S. Federal Regulations concerning the use of lead in paint and hydrocarbon emissions.
QUICK REFERENCE FOR APPLYING FIRE POLY 75 I
MATERIAL | APPLICATION | COVERAGE |
Interior wood any type of wood such as: Yellow Pine, Douglas fir, Cedar, and redwood |
Treat before, during or after construction. Be sure surface is clean and dry before treating. Apply with sprayer head held at 8 to 12 inches from surface. Apply with brush or roller. Treat all surface areas where possible Do not expose treated area to moisture for 24 hours. |
Apply three (3) coats at 500 sq. ft. per coat with the final coverage rate of 166.3 sq. ft. per gallon |
All surfaces to be treated must be clean
and dry. Fire Poly 75 I is water-based, clear liquid that
becomes insoluble when dry.
Fire Poly 75 I
also acts as a preservative, and water proofing agent. If over coating is intended, Fire
Poly 75 I is an excellent surface primer for use under
latex paints.
DO NOT DILUTE OR MIX FIRE POLY
75 I WITH ANY OTHER PRODUCTS.
Avoid wasteful runs and
dripping. It should be noted that unlike some
products, materials treated with Fire Poly 75-I
require no special cutting tools or special
fasteners. Contact parts of any equipment
should be stainless steel or plastic to prevent
chemical reaction and breakdown. Storage
may be done in polyethylene containers.
Structures under construction can be made fire resistant. As soon as the surface is enclosed, spray all exposed interior surfaces (studs, trusses, sub floor, joists, the interior of outside walls, etc.) with Fire Poly 75 I. This will provide the structure with a long-term fire retardant protection.
Fire Poly 75 I when applied according to the manufacturer’s specifications is the most effective fire retardant coating available.
CAUTION:
Product must not freeze. It must not be thinned or diluted.
OVERSPRAY:
The overspray will not harm plants or animals. Spills can be flushed with water. A rag wetted with bleach and water mix will clean up spotting.
CLEAN UP PROCEDURE:
Airless Equipment.
1. Run clear water through the system until coating is flushed out. When minor sudsing on surface stops, the system is flushed.
2. Run bleach and water mix (1 part to 4 parts) through system as solvent for cleaning any residue.
3. Repeat Step 1 if any foaming occurs in Step 2.
4. Lubricate system as specified by equipment manufacturer to combat rusting.
If two or more applications are planned in the same day, the sprayer can be kept clean by running water through the system between applications.
Brushes/Rollers.
1. Clean immediately after use.
2. Wash thoroughly with bleach and water mix (1 part to 4 parts).
SAFETY FIRST
Use approved safety devices (ropes, belts, ridge hooks, ladder, etc.) When working on steep or high areas. Take EXTREME CARE not to step on wet treated area. Surface may be slick until dry.
It is good practice to wear respirator or mask and protect hands with rubber gloves when spraying any coating or chemical. When engineered air control is not feasible, use properly maintained and properly fitted NIOSH approved respirator for solvent vapors. A dusk mask does not provide protection against vapors.
If eye contact occurs, flood with water for fifteen (15) minutes and call
a physician. KEEP OUT OF REACH OF CHILDREN. DO NOT TAKE
INTERNALLY.